Description
Specifications |
Maximum voltage between any terminal and earth ground | |
Surge protection | | 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 |
|
Fuse for A input | | 11 A, 1000 V FAST Fuse (Fluke PN 803293) |
|
Display | Digital: | 6,000 counts, updates 4 per second |
|
Bar graph | | 33 segments, updates 32 per second |
|
Operating Temperature | |
Storage Temperature | |
Battery type | | 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
|
Battery Life | | 400 hours typical, without backlight |
|
Accuracy Specifications |
DC millivolts | Range: | 600.0 mV | Resolution: | 0.1 mV | Accuracy: | ± ([% of reading] + [counts]): 2.0% + 3 |
|
DC volts | Range/Resolution: | 6.000 V / 0.001 V | Range/Resolution: | 60.00 V / 0.01 V | Range/Resolution: | 600.00 V / 0.1 V |
|
Auto volts | Range: | 600.0 V | Resolution: | 0.1 V | Accuracy: | 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz) |
|
AC millivolts1 true-rms | Range: | 600.0 mV | Resolution: | 0.1 mV | Accuracy: | 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
|
AC volts1 true-rms | Range/Resolution: | 6.000 V / 0.001 V | Range/Resolution: | 60.00 V / 0.01 V | Range/Resolution: | 600.0 V / 0.1 V | Accuracy: | 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
|
Continuity | Range: | 600 Ω | Resolution: | 1 Ω | Accuracy: | Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer. |
|
Ohms | Range/Resolution: | 600.0 Ω / 0.1 Ω | Range/Resolution: | 6.000 kΩ / 0.001 kΩ | Range/Resolution: | 60.00 kΩ / 0.01 kΩ | Range/Resolution: | 600.0 kΩ / 0.1 kΩ | Range/Resolution: | 6.000 MΩ / 0.001 MΩ | Accuracy: | 0.9 % + 1 | Range/Resolution: | 40.00 MΩ / 0.01 MΩ | Accuracy: | 1.5 % + 2 |
|
Diode Test | Range/Resolution: | 2.000 V / 0.001 V | Accuracy: | 0.9% + 2 |
|
Capacitance | Range/Resolution: | 1000 nF / 1 nF | Range/Resolution: | 10.00 μF / 0.01 μF | Range/Resolution: | 100.0 μF / 0.1 μF | Range/Resolution: | 9999 μF / 1 μF | Range/Resolution: | 100 μF to 1000 μF | Accuracy: | 1.9% + 2 | Range/Resolution: | > 1000 μF | Accuracy: | 5% + 20% |
|
LoZ capacitance | Range: | 1 nF to 500 μF | Accuracy: | 10% + 2 typical |
|
Temperature2 (Type-K thermocouple) | Range/Resolution: | -40 °C to 400 °C / 0.1 °C | Accuracy: | 1% + 102 | Range/Resolution: | -40 °F to 752 °C / 0.2 °F | Accuracy: | 1% + 182 |
|
AC amps true-rms (45 Hz to 500 Hz) | Range/Resolution: | 6.000 A / 0.001 A | Range/Resolution: | 10.00 A / 0.01 A | Accuracy: | 1.5% + 3 | | 20 A continuous overload for 30 seconds max |
|
DC amps | Range/Resolution: | 6.000 A / 0.001 A | Range/Resolution: | 10.00 A / 0.01 A | Accuracy: | 1.0% + 3 | | 20 A continuous overload for 30 seconds max |
|
Hz (V or A input)2 | Range/Resolution: | 99.99 Hz / 0.01 Hz | Range/Resolution: | 999.99 Hz / 0.1 Hz | Range/Resolution: | 9.999 Hz / 0.001 Hz | Range/Resolution: | 50.00 Hz / 0.01 Hz | Accuracy: | 0.1% + 2 |
|
Notes:
1) All ac voltage ranges are specified from 1 % to 100% of range. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled.
2) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage.
Mechanical & General Specifications |
Size | Height: | 27.62 cm (10.875″) | Length: | 15.875 cm (6.25″) | Width: | 5.6 cm (2.203″) |
|
Weight | |
Warranty | |
Reviews
There are no reviews yet.