Fluke 117/322 Electricians Multimeter and Clamp Meter Combo Kit

Rs.0

Feel free to contact us:
Mobile: 0344 3813810

This combo kit pairs the new Fluke 117 DMM with a Fluke 322 clamp meter for productive and effective troubleshooting in one total solution, including the new C115 durable soft carrying case for protection and easy meter transportation.

3 years warranty on Fluke 117 DMM, 2 years warranty on Fluke 322 Clamp meter and 1 year on accessories.

What’s Included:

  • Fluke 117 True-rms Digital Multimeter with non-contact voltage detector
  • NEW! Fluke C115 Deluxe carrying case with shoulder strap
  • Fluke 322 Compact Clamp Meter
  • Fluke TL75 Hard Point Test Lead Set
  • Fluke TPAK ToolPak Magnetic Meter Hanging Kit

Description

Specifications
Maximum voltage between any terminal and earth ground
600 V
Surge protection
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Fuse for A input
11 A, 1000 V FAST Fuse (Fluke PN 803293)
Display
Digital:6,000 counts, updates 4 per second
Bar graph
33 segments, updates 32 per second
Operating Temperature
-10 °C to + 50 °C
Storage Temperature
-40 °C to + 60 °C
Battery type
9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life
400 hours typical, without backlight

Accuracy Specifications
DC millivolts
Range:600.0 mV
Resolution:0.1 mV
Accuracy:± ([% of reading] + [counts]): 2.0% + 3
DC volts
Range/Resolution:6.000 V / 0.001 V
Range/Resolution:60.00 V / 0.01 V
Range/Resolution:600.00 V / 0.1 V
Auto volts
Range:600.0 V
Resolution:0.1 V
Accuracy:2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms
Range:600.0 mV
Resolution:0.1 mV
Accuracy:1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution:6.000 V / 0.001 V
Range/Resolution:60.00 V / 0.01 V
Range/Resolution:600.0 V / 0.1 V
Accuracy:1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range:600 Ω
Resolution:1 Ω
Accuracy:Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms
Range/Resolution:600.0 Ω / 0.1 Ω
Range/Resolution:6.000 kΩ / 0.001 kΩ
Range/Resolution:60.00 kΩ / 0.01 kΩ
Range/Resolution:600.0 kΩ / 0.1 kΩ
Range/Resolution:6.000 MΩ / 0.001 MΩ
Accuracy:0.9 % + 1
Range/Resolution:40.00 MΩ / 0.01 MΩ
Accuracy:1.5 % + 2
Diode Test
Range/Resolution:2.000 V / 0.001 V
Accuracy:0.9% + 2
Capacitance
Range/Resolution:1000 nF / 1 nF
Range/Resolution:10.00 μF / 0.01 μF
Range/Resolution:100.0 μF / 0.1 μF
Range/Resolution:9999 μF / 1 μF
Range/Resolution:100 μF to 1000 μF
Accuracy:1.9% + 2
Range/Resolution:> 1000 μF
Accuracy:5% + 20%
LoZ capacitance
Range:1 nF to 500 μF
Accuracy:10% + 2 typical
Temperature2 (Type-K thermocouple)
Range/Resolution:-40 °C to 400 °C / 0.1 °C
Accuracy:1% + 102
Range/Resolution:-40 °F to 752 °C / 0.2 °F
Accuracy:1% + 182
AC amps true-rms (45 Hz to 500 Hz)
Range/Resolution:6.000 A / 0.001 A
Range/Resolution:10.00 A / 0.01 A
Accuracy:1.5% + 3
20 A continuous overload for 30 seconds max
DC amps
Range/Resolution:6.000 A / 0.001 A
Range/Resolution:10.00 A / 0.01 A
Accuracy:1.0% + 3
20 A continuous overload for 30 seconds max
Hz (V or A input)2
Range/Resolution:99.99 Hz / 0.01 Hz
Range/Resolution:999.99 Hz / 0.1 Hz
Range/Resolution:9.999 Hz / 0.001 Hz
Range/Resolution:50.00 Hz / 0.01 Hz
Accuracy:0.1% + 2

Notes:
1) All ac voltage ranges are specified from 1 % to 100% of range. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled.
2) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage.

Mechanical & General Specifications
Size
Height:27.62 cm (10.875″)
Length:15.875 cm (6.25″)
Width:5.6 cm (2.203″)
Weight
0.607 kg (1.34#)
Warranty
3 years

Reviews

There are no reviews yet.

Be the first to review “Fluke 117/322 Electricians Multimeter and Clamp Meter Combo Kit”

Your email address will not be published. Required fields are marked *